Property Data Test
R-Value 6.9 @1″
21.0 @ 3″
ASTM C-518
Core Density 2.0 LB/Cubic Foot ASTM D-1622
Closed Cell Content > 90% ASTM D-2856
Sound Transmission Coefficient 41 ASTM E-90-85/E 413
Water Absorption < 2% by volume ASTM D-2842
Water Vapor Transmission – Permeance 0.8 Perms @ 1″
0.23 Perms @ 3.5″
ASTM E-96
Air Impermeable < 0.02 (L/s-m2) @ 1″ ASTM E-2178
Tensile Strength (PSI) > 60  psi ASTM D-1623
Dimensional Stability < 9% ASTM D-2126
Compressive Strength 47 psi ASTM D-1621